The 600t stiff leg derrick Columbia Giant relocated to Charleston, SC. We were
retained to reevaluate the crane capacity and to develop a new load chart
based on the specified design codes. We also designed the new crane
foundation, the concrete dead-man, and the backstay support structure. We
developed the overload testing scheme and witnessed the load tests. The
calculation packages and detail engineering drawings were provided to our
clients. |
|